NSN 6530-00-148-7317 RK600, RK625, 00-148-7317
Product Details | PATIENT THERMOREGULATOR
6530-00-148-7317 An item designed to lower or raise the body temperature of the patient during surgery, as well as quickly reducing and controlling dangerously high temperatures of postoperative infections. Temperature readings can be made esophageally or rectally by the use of thermistor sensing probes.
Part Alternates: RK600, RK625, 6530-00-148-7317, 00-148-7317, 6530001487317, 001487317
Medical, Dental, and Veterinary Equipment and Supplies | Hospital Furniture, Equipment, Utensils, and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 07 AUG 1974 | 00-148-7317 | 28787 ( THERMOREGULATOR, PATIENT ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6530-00-148-7317
Related Products | NSN 6530-00-148-7317
Technical Data | NSN 6530-00-148-7317
| Characteristic | Specifications |
|---|---|
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | 1000 WATTS; SOLID STATE 115/220 VOLTS,50/60 HZ AC; C/OELECTRICALLY OPERATED HEAT EXCHANGER W/BASIC CONTROL AND SUPPLEMENTARY ELECTRONIC CONTROL,MOUNTED ON PEDESTAL-TYPE MOBILE STAND; PAD TEMPERATURE ELECTRICALLY CONTROLLED; PATIENT TEMPERATURE MAINTAINED MANUALLY OR BY ELECTRONIC CONTROL; W/PATIENT PROBE JACK FOR CONNECTING TO THERMISTOR PROBE PLUG; SEPARATE BATTERY-OPERATED PROBE THERMOMETER CAPABLE OF MONITORING 2 PATIENTS EACH; FOR INDUCING AND CONTROLLING HYPOTHERMIA DURING SURGERY AND FOR REDUCING AND CONTROLLING HIGH TEMPERATURES; REQUISITION SHOULD SPECIFY VOLTAGE AND FREQUENCY REQUIRED OR IF ANY OPTIONAL ACCESSORIES ARE DESIRED |
| III EXTERIOR CONTAINER QUANTITY | 1 |
| III UNIT OF ISSUE WEIGHT | 175.00 POUNDS |
| III EXTERIOR CONTAINER WEIGHT | 175.00 POUNDS |
| III UNIT OF ISSUE CUBE | 15.500 CUBIC FEET |
| III EXTERIOR CONTAINER CUBIC MEASURE | 15.50 CUBIC FEET |
Restrictions/Controls & Freight Information | NSN 6530-00-148-7317
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 188340 | VALVES THEMOSTATIC NOI/THEMOSTATS |
| Less than car load rating | ||
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 534 | unknown |
| Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | M | Medical supplies, equipment, samples records, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |