Product Details | PATIENT THERMOREGULATOR

6530-00-148-7317 An item designed to lower or raise the body temperature of the patient during surgery, as well as quickly reducing and controlling dangerously high temperatures of postoperative infections. Temperature readings can be made esophageally or rectally by the use of thermistor sensing probes.

Part Alternates: RK600, RK625, 6530-00-148-7317, 00-148-7317, 6530001487317, 001487317

Medical, Dental, and Veterinary Equipment and Supplies | Hospital Furniture, Equipment, Utensils, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 07 AUG 1974 00-148-7317

Cross Reference | NSN 6530-00-148-7317

Part Number Cage Code Manufacturer
RK600 25567 GORMAN-RUPP COMPANY, THE DBA MANSFIELD DIVISION
RK625 25567 GORMAN-RUPP COMPANY, THE DBA MANSFIELD DIVISION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6530-00-148-7317

Technical Data | NSN 6530-00-148-7317

Characteristic Specifications
GENERAL CHARACTERISTICS ITEM DESCRIPTION 1000 WATTS; SOLID STATE 115/220 VOLTS,50/60 HZ AC; C/OELECTRICALLY OPERATED HEAT EXCHANGER W/BASIC CONTROL AND SUPPLEMENTARY ELECTRONIC CONTROL,MOUNTED ON PEDESTAL-TYPE MOBILE STAND; PAD TEMPERATURE ELECTRICALLY CONTROLLED; PATIENT TEMPERATURE MAINTAINED MANUALLY OR BY ELECTRONIC CONTROL; W/PATIENT PROBE JACK FOR CONNECTING TO THERMISTOR PROBE PLUG; SEPARATE BATTERY-OPERATED PROBE THERMOMETER CAPABLE OF MONITORING 2 PATIENTS EACH; FOR INDUCING AND CONTROLLING HYPOTHERMIA DURING SURGERY AND FOR REDUCING AND CONTROLLING HIGH TEMPERATURES; REQUISITION SHOULD SPECIFY VOLTAGE AND FREQUENCY REQUIRED OR IF ANY OPTIONAL ACCESSORIES ARE DESIRED
III EXTERIOR CONTAINER QUANTITY 1
III UNIT OF ISSUE WEIGHT 175.00 POUNDS
III EXTERIOR CONTAINER WEIGHT 175.00 POUNDS
III UNIT OF ISSUE CUBE 15.500 CUBIC FEET
III EXTERIOR CONTAINER CUBIC MEASURE 15.50 CUBIC FEET

Restrictions/Controls & Freight Information | NSN 6530-00-148-7317

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 188340 VALVES THEMOSTATIC NOI/THEMOSTATS
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 534 unknown
Originating Activity Code KX Defense Supply Center Philadelphia
Philiadelphia, PA 19101
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity M Medical supplies, equipment, samples records, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable