Product Details | FREQUENCY CALIBRATOR

6625-00-242-3959 An item which generates a highly accurate signal of one or more fixed frequencies for calibration of frequencies from other sources. Does not include OSCILLATOR (as modified). For devices which are designed as voltage sources, see GENERATOR, SIGNAL. See also FREQUENCY METER.

Part Alternates: SMA5716231, SMA571623-1, FE12AFREQCALIBRAT0R, 6625-00-242-3959, 00-242-3959, 6625002423959, 002423959

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 19 MAR 1971 00-242-3959

Cross Reference | NSN 6625-00-242-3959

Part Number Cage Code Manufacturer
FE12AFREQCALIBRAT0R 14844 FREQUENCY ELECTRONICS, INC. DIV FREQUENCY ELECTRONICS, INC.
SMA571623-1 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-242-3959

Technical Data | NSN 6625-00-242-3959

Characteristic Specifications
INDIVIDUAL CHANNEL QUANTITY 3
INDIVIDUAL CHANNEL FREQUENCY 5.0 MEGAHERTZ NOMINAL AND 1.0 MEGAHERTZ NOMINAL AND 100.0 KILOHERTZ NOMINAL
INTERNAL CALIBRATION CRYSTAL NOT INCLUDED
DC VOLTAGE RATING 28.0 VOLTS NOMINAL
INTERNAL BATTERY ACCOMMODATION NOT INCLUDED
OVERALL LENGTH 14.312 INCHES NOMINAL
OVERALL WIDTH 5.500 INCHES NOMINAL
OVERALL HEIGHT 4.750 INCHES NOMINAL
CASE MATERIAL METAL
CASE SURFACE TREATMENT ENAMEL
MOUNTING METHOD HOLE
MANUFACTURERS CODE 80063
DESIGN CONTROL REFERENCE SMA571623-1

Restrictions/Controls & Freight Information | NSN 6625-00-242-3959

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Automatic Data Processing Equipment:8ADP Components. Represents ADP component assemblies that are parts of analog, digital, or hybrid data processing devices.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code CL U.S. Army Communications-Electronics
Fort Monmouth, NJ 07703-5006
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-00-242-3959

Category Code Description
Materiel Category and Inventory ManagerG Communications and Electronics Equipment, Electronics Materiel
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment1 REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance.
Specific Group/Generic Code4 Communications Systems Agency and Satellite Communications
Weapons Systems/End Item or Homogeneous Group4AAN/FSC-78/GSC-39
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplyB16US Army Communications-Electronics
Command and Fort Monmouth
Fort Monmouth, NJ 07703-5016
AgencyDADepartment of the Army
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityDWhen repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level.
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9YNavy-owned stocks of material managed by the Army within the Army Communications and Electronics Materiel Readiness Command
Naval Inventory Control Point, Mechanicsburg
Source of SupplyB16US Army Communications-Electronics
Command and Fort Monmouth
Fort Monmouth, NJ 07703-5016
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesEOTHER SERVICE-MANAGED, STOCKED, AND ISSUED (For Service use only if Secondary Inventory Control Activity Level of Authority (SICA LOA) is 8D and Nonconsumable Item Material Support Code (NIMSC) is 6.) Issue, transfer or shipment is not subject to specialized controls other than those imposed by the Service requisitioning policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions may require a fund citation and will be submitted in accordance with the Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each