NSN 5905-01-243-6741 1406001T, 140-6001T, 4431316011
Product Details | NONINDUCTIVE WIRE WOUND FIXED RESISTOR
5905-01-243-6741 INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.
Part Alternates: 1406001T, 140-6001T, 4431316011, 443-1316-011, 5905-01-243-6741, 01-243-6741, 5905012436741, 012436741
Electrical and Electronic Equipment Components | Resistors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 31 OCT 1986 | 01-243-6741 | 37404 ( RESISTOR, FIXED, WIRE WOUND, NONINDUCTIVE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5905-01-243-6741
Related Products | NSN 5905-01-243-6741
Technical Data | NSN 5905-01-243-6741
| Characteristic | Specifications |
|---|---|
| ELECTRICAL RESISTANCE | 6.000 KILOHMS |
| RESISTANCE TOLERANCE IN PERCENT | -0.010 TO 0.010 |
| POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -20.0 TO 20.0 |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0 TO 125.0 |
| INCLOSURE METHOD | ENCAPSULATED |
| STYLE DESIGNATOR | 14 AXIAL TERMINAL EACH END |
| BODY DIAMETER | 0.125 INCHES NOMINAL |
| BODY LENGTH | 0.250 INCHES NOMINAL |
| TERMINAL TYPE | WIRE LEAD |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | 2.000 INCHES NOMINAL |
| III END ITEM IDENTIFICATION | LGM30F/G |
| (NON-CORE DATA) CUBIC MEASURE | 0.003 CUBIC INCHES |
Restrictions/Controls & Freight Information | NSN 5905-01-243-6741
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 062960 | REOSTATS/PARTS NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |