Product Details | NONIND WIRE WOUND FIXED RESISTOR

5905-01-596-5534 INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.

Part Alternates: MIL-PRF-39007/8, MILPRF390078, RWR80N3351BP, 5905-01-596-5534, 01-596-5534, 5905015965534, 015965534

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 19-MAY-11 01-596-5534

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-596-5534

Technical Data | NSN 5905-01-596-5534

Characteristic Specifications
REACTANCE CHARACTERISTIC NONINDUCTIVE
RELIABILITY INDICATOR ESTABLISHED
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 250.0
RESISTANCE TOLERANCE IN PERCENT -0.100/+0.100 EACH RESISTOR
BODY LENGTH 0.406 INCHES NOMINAL
BODY DIAMETER 0.094 INCHES NOMINAL
ELECTRICAL RESISTANCE 3.350 KILOHMS EACH RESISTOR
POWER DISSIPATION RATING IN WATTS 2.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 25.0
TERMINAL TYPE WIRE LEAD
STYLE DESIGNATOR AXIAL TERMINAL EACH END
RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.100
TERMINAL LENGTH 1.500 INCHES NOMINAL
INCLOSURE METHOD ENCAPSULATED

Restrictions/Controls & Freight Information | NSN 5905-01-596-5534

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description