NSN 5915-00-058-4982 B740A, C38253, C-38253
Product Details | BAND PASS FILTER
5915-00-058-4982 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Part Alternates: B740A, C38253, C-38253, 535A, 5915-00-058-4982, 00-058-4982, 5915000584982, 000584982
Electrical and Electronic Equipment Components | Filters and Networks
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 01 JAN 1961 | 00-058-4982 | 00209 ( FILTER, BAND PASS ) |
Cross Reference | NSN 5915-00-058-4982
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 535A | 03040 | POWER CONTROL DEVICES, INC. DBA AMERICAN TIME PRODUCTS |
| 535A | 28726 | BULOVA TECHNOLOGIES L.L.C. DBA ENVIRONMENTAL SYSTEMS & SVCS |
| B740A | 56662 | FREQUENCY SELECTIVE NETWORKS INC |
| C-38253 | 73293 | L-3 COMMUNICATIONS ELECTRON TECHNOLOGIES, INC. |
| C38253 | 42498 | DAR ELECTRONICS INC DBA NATIONAL RADIO CO |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5915-00-058-4982
Related Products | NSN 5915-00-058-4982
Technical Data | NSN 5915-00-058-4982
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | 140.0 KILOHERTZ BLANK |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 10.0 BLANK |
| FREQUENCY BAND WIDTH PER FUNCTION | 139.875 KILOHERTZ BLANK AND 140.175 KILOHERTZ BLANK |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | 22.0 KILOHMS BLANK |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 10.0 KILOHMS BLANK |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TURRET INPUT 2 TURRET OUTPUT |
| STYLE DESIGNATOR | 2 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| OVERALL HEIGHT | 3.000 INCHES MAXIMUM |
| BODY LENGTH | 4.500 INCHES NOMINAL |
| BODY HEIGHT | 2.500 INCHES NOMINAL |
| BODY WIDTH | 2.680 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.000 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.250 INCHES NOMINAL |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| NOMINAL THREAD SIZE | 0.164 INCHES |
| III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 110.00 KILOHERTZ BLANK AND 139.825 KILOHERTZ BLANK AND 140.175 KILOHERTZ BLANK AND 170.00 KILOHERTZ BLANK |
| III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM BLANK AND 6.0 MAXIMUM BLANK AND 6.0 MAXIMUM BLANK AND 60.0 MINIMUM BLANK |
| III OPERATING TEMP RANGE | -10.0 TO 85.0 DEG CELSIUS |
| III BODY MATERIAL | METAL |
Restrictions/Controls & Freight Information | NSN 5915-00-058-4982
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 593 | unknown |
| Originating Activity Code | XX | |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-058-4982
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |