Product Details | BAND PASS FILTER

5915-01-118-7462 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).

Part Alternates: 2931341, 293-1341 , 2931341010, 293-1341-010, 3791FTR, 3791-FTR , 7156, 5915-01-118-7462, 01-118-7462, 5915011187462, 011187462

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 10 SEP 1981 01-118-7462

Drawings & Photos | NSN 5915-01-118-7462


Demand History | NSN 5915-01-118-7462

Part Number Request Date QTY Origin
5915-01-118-7462 2025-08-236 48 DIBBS
5915-01-118-7462 2025-07-188 46 DIBBS
5915-01-118-7462 2018-08-221 116 DIBBS
5915-01-118-7462 2018-07-197 38 DIBBS
5915-01-118-7462 2018-06-170 49 DIBBS
5915-01-118-7462 2017-10-288 30 DIBBS
5915-01-118-7462 2017-04-108 1 DIBBS-RFPs
5915-01-118-7462 2017-01-16 30 DIBBS
5915-01-118-7462 2016-06-161 63 DIBBS
5915-01-118-7462 2016-01-26 33 DIBBS
5915-01-118-7462 2015-05-148 30 DIBBS
5915-01-118-7462 2015-01-15 24 DIBBS
5915-01-118-7462 2013-11-332 20 DIBBS
5915-01-118-7462 2013-09-260 100 DIBBS
5915-01-118-7462 2010-12-342 29 DIBBS
5915-01-118-7462 2009-11-317 23 DIBBS
5915-01-118-7462 2009-10-299 6 DIBBS
5915-01-118-7462 2008-10-294 33 DIBBS
5915-01-118-7462 2007-12-347 13 DIBBS

Cross Reference | NSN 5915-01-118-7462

Part Number Cage Code Manufacturer
293-1341 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
293-1341-010 00136 VECTRON INTERNATIONAL, INC.
293-1341-010 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
293-1341-010 1P972 MASON WINLECTRIC COMPANY DBA WARREN COUNTY ELECTRIC SUPPLY
293-1341-010 62744 THOMSON-CSF ELECTRON TUBE DIV
3791-FTR 0S4G1 PRECISION DEVICES, INC. DBA P D I
7156 25120 PIEZO TECHNOLOGY, INC. DBA MTRONPTI

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-118-7462

Technical Data | NSN 5915-01-118-7462

Characteristic Specifications
REFERENCE FREQUENCY PER FUNCTION 97.8 MEGAHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS 5.0 BLANK
FREQUENCY BAND WIDTH PER FUNCTION 97.50 MEGAHERTZ BLANK AND 98.10 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION 100.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION 100.0 OHMS BLANK
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 PIN INPUT 1 PIN OUTPUT 6 PIN GROUND
STYLE DESIGNATOR 2 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
OVERALL HEIGHT 0.740 INCHES NOMINAL
BODY LENGTH 2.250 INCHES NOMINAL
BODY HEIGHT 0.600 INCHES MAXIMUM
BODY WIDTH 0.750 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 8 TERMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.900 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.450 INCHES NOMINAL
III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION 96.80 MEGAHERTZ BLANK AND 97.50 MEGAHERTZ BLANK AND 98.10 MEGAHERTZ BLANK AND 98.80 MEGAHERTZ BLANK
III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS 60.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK AND 1.0 MAXIMUM BLANK AND 60.0 MINIMUM BLANK
III OPERATING TEMP RANGE -55.0 TO 100.0 DEG CELSIUS
III BODY MATERIAL METAL

Restrictions/Controls & Freight Information | NSN 5915-01-118-7462

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 593 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-118-7462

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each