NSN 5915-01-205-1822 5054, 9191304, 919-1304
Product Details | BAND PASS FILTER
5915-01-205-1822 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Part Alternates: 5054, 9191304, 919-1304, 5915-01-205-1822, 01-205-1822, 5915012051822, 012051822
Electrical and Electronic Equipment Components | Filters and Networks
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 04 APR 1985 | 01-205-1822 | 00209 ( FILTER, BAND PASS ) |
Demand History | NSN 5915-01-205-1822
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5915-01-205-1822 | 2006-07-194 | 3 | DIBBS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5915-01-205-1822
Related Products | NSN 5915-01-205-1822
Technical Data | NSN 5915-01-205-1822
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | 9.0 MEGAHERTZ BLANK |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 10.0 BLANK |
| FREQUENCY BAND WIDTH PER FUNCTION | 840.00 KILOHERTZ BLANK AND 1.16 GIGAHERTZ BLANK |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS BLANK |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS BLANK |
| INCLOSURE TYPE | ENCASED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 WIRE LEAD INPUT 1 WIRE LEAD OUTPUT |
| STYLE DESIGNATOR | 2 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| OVERALL HEIGHT | 1.005 INCHES NOMINAL |
| BODY LENGTH | 1.600 INCHES MAXIMUM |
| BODY HEIGHT | 0.625 INCHES MAXIMUM |
| BODY WIDTH | 0.760 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL |
| III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 675.00 KILOHERTZ BLANK AND 840.00 KILOHERTZ BLANK AND 1.16 GIGAHERTZ BLANK AND 1.33 GIGAHERTZ BLANK |
| III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM BLANK AND 2.0 MAXIMUM BLANK AND 2.0 MAXIMUM BLANK AND 60.0 MINIMUM BLANK |
| III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | CRYSTAL BLANK |
| III OPERATING TEMP RANGE | -30.0 TO 80.0 DEG CELSIUS |
| III BODY MATERIAL | METAL |
Restrictions/Controls & Freight Information | NSN 5915-01-205-1822
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 593 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-01-205-1822
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |