Product Details | BAND PASS FILTER

5915-01-276-8095 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).

Part Alternates: BPFC60210210675, BPF-C-602-102-10675, F5593, F-5593, 292471P3, 8B250-6000/U1000-0/0, 8B2506000U100000, 5915-01-276-8095, 01-276-8095, 5915012768095, 012768095

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 13 APR 1988 01-276-8095

Drawings & Photos | NSN 5915-01-276-8095


Cross Reference | NSN 5915-01-276-8095

Part Number Cage Code Manufacturer
292471P3 94117 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
8B250-6000/U1000-0/0 50140 K&L MICROWAVE, INC.
BPF-C-602-102-10675 56216 TELEDYNE WIRELESS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS
F-5593 12598 R L C ELECTRONICS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-276-8095

Technical Data | NSN 5915-01-276-8095

Characteristic Specifications
REFERENCE FREQUENCY PER FUNCTION 6.0 GIGAHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS 2.0 BLANK
FREQUENCY BAND WIDTH PER FUNCTION 5.50 GIGAHERTZ BLANK AND 6.50 GIGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION 1.6 BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION 5.5 GIGAHERTZ BLANK AND 6.5 GIGAHERTZ BLANK
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 1 CONNECTOR, RECEPTACLE OUTPUT
STYLE DESIGNATOR 26 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 2.540 INCHES MINIMUM AND 2.660 INCHES MAXIMUM
BODY OUTSIDE DIAMETER 0.230 INCHES MINIMUM AND 0.270 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 TERMINAL
III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION 5.00 GIGAHERTZ BLANK AND 5.50 GIGAHERTZ BLANK AND 6.50 GIGAHERTZ BLANK AND 7.00 GIGAHERTZ BLANK
III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS 30.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK AND 1.0 MAXIMUM BLANK AND 30.0 MINIMUM BLANK
III AVERAGE POWER RATING PER FUNCTION 4.0 WATTS BLANK
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE BLANK
III INPUT TERMINAL MANUFACTURER CODE 12598
III INPUT TERMINAL IDENTIFICATION SMA-RECEPTACLE
III OUTPUT TERMINAL MANUFACTURER CODE 12598
III OUTPUT TERMINAL IDENTIFICATION SMA-RECEPTACLE
III VIBRATION RESISTANCE RANGE IN HERTZ 10.0 TO 500.0
III OPERATING TEMP RANGE -25.0 TO 85.0 DEG CELSIUS
III BODY MATERIAL METAL

Restrictions/Controls & Freight Information | NSN 5915-01-276-8095

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 593 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-276-8095

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each