Product Details | SENSITIVE SWITCH

5930-00-307-4818 A switch with a quick-acting mechanism actuated by a highly delicate tactile contact. Includes membrane switch. Excludes SWITCH, FLEXIBLE; SWITCH, PRESSURE; and SWITCH, THERMOSTATIC.

Part Alternates: EXQ800, 5930-00-307-4818, 00-307-4818, 5930003074818, 003074818

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 19 OCT 1973 00-307-4818

Drawings & Photos | NSN 5930-00-307-4818


Cross Reference | NSN 5930-00-307-4818

Part Number Cage Code Manufacturer
EXQ800 91929 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-307-4818

Technical Data | NSN 5930-00-307-4818

Characteristic Specifications
NONPILE-UP CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT
MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 15.000 AMPERES MOTOR AC
BODY STYLE 17M BUSHING/HOLE MOUNTED
BODY LENGTH 3.660 INCHES NOMINAL
BODY WIDTH 2.015 INCHES NOMINAL
BODY HEIGHT 2.560 INCHES NOMINAL
SWITCH ACTUATOR QUANTITY 1
ACTUATOR STYLE 6 ROUND
ACTUATOR DIAMETER 0.330 INCHES NOMINAL
ACTUATOR HEIGHT 1.859 INCHES NOMINAL
INCLOSURE TYPE FULLY INCLOSED
UNTHREADED MOUNTING HOLE DIAMETER 0.190 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNF
NOMINAL THREAD SIZE 0.190 INCHES
III END ITEM IDENTIFICATION GENERATO,HYDROGEN,ELECTROLYTIC, STUART M-28

Restrictions/Controls & Freight Information | NSN 5930-00-307-4818

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information