Product Details | SENSITIVE SWITCH

5930-00-913-7960 A switch with a quick-acting mechanism actuated by a highly delicate tactile contact. Includes membrane switch. Excludes SWITCH, FLEXIBLE; SWITCH, PRESSURE; and SWITCH, THERMOSTATIC.

Part Alternates: MS250852, MS25085-2, M2480843141, M2480-843141 , M88052002, M8805-2-002, MIL-S-8805/2, MILS88052, 1212L6, 121-2L6, 4520011002, 452-0011-002, 5930-00-913-7960, 00-913-7960, 5930009137960, 009137960

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1960 00-913-7960

Drawings & Photos | NSN 5930-00-913-7960


Demand History | NSN 5930-00-913-7960

Part Number Request Date QTY Origin
5930-00-913-7960 2025-06-153 133 DIBBS
5930-00-913-7960 2025-05-142 133 DIBBS
5930-00-913-7960 2025-04-111 109 DIBBS
5930-00-913-7960 2025-04-100 109 DIBBS
MS250852 2025-04-97 2 Japan
M88052002 2023-10-276 4 Korea
M88052002 2023-08-243 2 Korea
5930-00-913-7960 2022-07-196 42 Malaysia
5930-00-913-7960 2020-02-37 271 DIBBS
5930-00-913-7960 2018-08-242 113 DIBBS
5930-00-913-7960 2017-10-283 4 Malaysia
5930-00-913-7960 2014-01-13 382 DIBBS
5930-00-913-7960 2013-08-218 69 DIBBS
5930-00-913-7960 2009-06-153 500 DIBBS
5930-00-913-7960 2007-12-358 10 Taiwan

Cross Reference | NSN 5930-00-913-7960

Part Number Cage Code Manufacturer
121-2L6 82005 ALLARD NAZARIAN GROUP, INC. DBA GRANITE STATE MANUFACTURING
452-0011-002 94756 BOEING COMPANY, THE DBA BOEING
M2480-843141 SZ003 FORSVARETS MATERIELVERK DEFENCEMATERIEL ADMINISTRATION
M8805-2-002 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-S-8805/2 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MS25085-2 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MS25085-2 96906 MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-913-7960

Technical Data | NSN 5930-00-913-7960

Characteristic Specifications
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT
MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.000 AMPERES RESISTIVE DC AND 3.000 AMPERES INDUCTIVE DC AND 5.000 AMPERES RESISTIVE AC AND 5.000 AMPERES INDUCTIVE AC AND 1.500 AMPERES LAMP AC
BODY STYLE 20M HOLE MOUNTED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.373 INCHES MINIMUM AND 0.377 INCHES MAXIMUM
BODY LENGTH 0.771 INCHES MINIMUM AND 0.791 INCHES MAXIMUM
BODY WIDTH 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM
BODY HEIGHT 0.349 INCHES MINIMUM AND 0.369 INCHES MAXIMUM
OVERALL LENGTH 0.781 INCHES NOMINAL
OVERALL WIDTH 0.250 INCHES NOMINAL
OVERALL HEIGHT 0.609 INCHES MAXIMUM
ACTUATOR STYLE 8 ROUND
ACTUATOR DIAMETER 0.087 INCHES MINIMUM AND 0.097 INCHES MAXIMUM
ACTUATOR HEIGHT 0.110 INCHES MAXIMUM
ACTUATOR FREE POSITION HEIGHT 0.375 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 3 TURRET
SWITCH ACTUATING FORCE 5.0 OUNCES MAXIMUM
SWITCH RELEASE FORCE 1.0 OUNCES MINIMUM
ACTUATOR MOVEMENT 0.030 PRETRAVEL INCHES MAXIMUM AND 0.005 OVERTRAVEL INCHES MINIMUM AND 0.004 DIFFERENTIAL INCHES MAXIMUM
INCLOSURE TYPE FULLY INCLOSED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION FLAMEPROOF
MOUNTING METHOD UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.087 INCHES MINIMUM AND 0.090 INCHES MAXIMUM
TEST DATA DOCUMENT 81349-MIL-S-8805 SPECIFICATION
SPECIFICATION/STANDARD DATA 96906-MS-25085 GOVERNMENT STANDARD
III CASE MATERIAL PLASTIC
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-S-8805/2
MANUFACTURERS CODE 96906
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MS25085-2

Restrictions/Controls & Freight Information | NSN 5930-00-913-7960

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-00-913-7960

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment3 INSURANCE ITEMS. This code will identify items for which there may be occasional intermittent demands not sufficiently repetitive to warrant classification as regular stock items, but for which prudence requires that nominalquan tity be stocked for the reason that the essentiality of the item and the long lead time required to obtain such items by purchase would create an unacceptable situation if no stock were carried.
Specific Group/Generic CodeT Other Electronics Equipment
Weapons Systems/End Item or Homogeneous GroupTQRechargeable batteries
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Price ValidationV The current standard price has been validated.
  • The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
  • The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
  • ZOP or Standard price challenges are permissible but must be supported by adequate justification.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each