Product Details | ELECTRICAL DUMMY LOAD

5985-00-033-9476 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Part Alternates: 150A426G10, 5985-00-033-9476, 00-033-9476, 5985000339476, 000339476

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-033-9476

Cross Reference | NSN 5985-00-033-9476

Part Number Cage Code Manufacturer
150A426G10 79500 WESTINGHOUSE ELECTRIC CORP
150A426G10 97942 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-033-9476

Technical Data | NSN 5985-00-033-9476

Characteristic Specifications
FREQUENCY RANGE RATING 2.320 TO 2.680 GIGAHERTZ
POWER RATING 250.000 KILOWATTS PEAK AND 500.000 WATTS AVERAGE
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER -10.0 AND 52.0
IMPEDANCE RATING IN OHMS NOT RATED
VOLTAGE STANDING WAVE RATIO 1.20
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE 2.320 TO 2.680 GIGAHERTZ
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE 4.0 POUNDS PER SQUARE INCH GAGE
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
SPECIAL FEATURES ALUMINUM; CHEMICAL FILM,PRIMER AND PAINT
III RF CONNECTOR CHANGING FEATURE NOT INCLUDED
III FRAGILITY FACTOR MODERATELY RUGGED
III END ITEM IDENTIFICATION RADAR SET AN/FPS-27
III FSC APPLICATION DATA ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT

Restrictions/Controls & Freight Information | NSN 5985-00-033-9476

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information