Product Details | ELECTRICAL DUMMY LOAD

5985-00-149-9414 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Part Alternates: 11366500KW, 11366-500KW, 5985-00-149-9414, 00-149-9414, 5985001499414, 001499414

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 29 SEP 1971 00-149-9414

Cross Reference | NSN 5985-00-149-9414

Part Number Cage Code Manufacturer
11366-500KW 27192 DRS POWER & CONTROL TECHNOLOGIES, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-149-9414

Technical Data | NSN 5985-00-149-9414

Characteristic Specifications
III END ITEM IDENTIFICATION USED ON A TEST SET TO TEST GENERATORS

Restrictions/Controls & Freight Information | NSN 5985-00-149-9414

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 72D unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-00-149-9414

Category Code Description
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeQCTG:ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each