Product Details | ELECTRICAL DUMMY LOAD

5985-01-504-3595 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Part Alternates: 588CPRG, 588-CPRG, 5985-01-504-3595, 01-504-3595, 5985015043595, 015043595

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 27 JAN 2003 01-504-3595

Cross Reference | NSN 5985-01-504-3595

Part Number Cage Code Manufacturer
588-CPRG 00443 WAVELINE INCORPORATED

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-504-3595

Technical Data | NSN 5985-01-504-3595

Characteristic Specifications
OVERALL LENGTH 14.750 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 4.120 INCHES NOMINAL
OVERALL HEIGHT 2.875 INCHES NOMINAL
OVERALL WIDTH 3.630 INCHES NOMINAL
FREQUENCY RANGE RATING 7.050 TO 10.000 GIGAHERTZ
POWER RATING 2500.000 WATTS AVERAGE
VOLTAGE STANDING WAVE RATIO 1.10
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE 35.0 POUNDS PER SQUARE INCH GAGE
COOLING METHOD FORCED AIR
BLOWER UNIT MOTOR CURRENT TYPE AC
BLOWER UNIT MOTOR VOLTAGE RATING IN VOLTS 115.0
BLOWER UNIT MOTOR FREQUENCY IN HERTZ 50.0 AND 60.0

Restrictions/Controls & Freight Information | NSN 5985-01-504-3595

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description